TRYS Site Information Form (site log) French GPS Permanent network (RGP) See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : RGP Team Date Prepared : 2022-03-15 Report Type : UPDATE If Update: Previous Site Log : trys_20160201.log Modified/Added Sections : 3.4, 3.5 1. Site Identification of the GNSS Monument Site Name : Troyes Four Character ID : TRYS Monument Inscription : NONE IERS DOMES Number : 10083M102 CDP Number : NONE Monument Description : ALUMINIUM PLATE ON TOP OF THREE RODS Height of the Monument : 0.15m Monument Foundation : CONCRETE WALL Foundation Depth : Marker Description : TOP AND CENTRE OF THE ALUMINIUM PLATE Date Installed : 2001-11-27T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : NO Distance/activity : Additional Information : 2. Site Location Information City or Town : Troyes State or Province : Aube (10) Country : France Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4241041.85 Y coordinate (m) : 297441.47 Z coordinate (m) : 4738832.15 Latitude (N is +) : +481739.28 Longitude (E is +) : +0040042.54 Elevation (m,ellips.) : 168.4 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 00009809 Firmware Version : 7.29 / 3.07 Elevation Cutoff Setting : 5 Date Installed : 2001-11-27T00:00Z Date Removed : 2007-10-16T00:00Z Temperature Stabiliz. : none Additional Information : 9 chanels 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 3508A09839 Firmware Version : 7.32 / 3.08 Elevation Cutoff Setting : 5 Date Installed : 2007-10-16T00:00Z Date Removed : 2008-04-23 Temperature Stabiliz. : none Additional Information : 9 chanels 3.3 Receiver Type : TRIMBLE 5700 Satellite System : GPS Serial Number : 0220360676 Firmware Version : 2.21 Elevation Cutoff Setting : 5 Date Installed : 2008-04-23 Date Removed : 2011-03-28T00:00Z Temperature Stabiliz. : none Additional Information : 3.4 Receiver Type : TRIMBLE NETR5 Satellite System : GPS+GLO Serial Number : 5035K69958 Firmware Version : 4.19 Elevation Cutoff Setting : 5 Date Installed : 2011-03-28T14:00Z Date Removed : 2022-02-21T16:00Z Temperature Stabiliz. : none Additional Information : 3.5 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO Serial Number : 6139R40180 Firmware Version : 5.44 Elevation Cutoff Setting : 5 Date Installed : 2022-02-21T16:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+CMP+QZSS+SBAS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM22020.00+GP NONE Serial Number : 0220013594 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 10 Date Installed : 2001-11-27T00:00Z Date Removed : 2008-04-23T00:00Z Additional Information : (multiple lines) 4.2 Antenna Type : TRM41249.00 NONE Serial Number : 60041117 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 10 Date Installed : 2008-04-23T00:00Z Date Removed : 2011-03-28T00:00Z Additional Information : (multiple lines) 4.3 Antenna Type : TRM55971.00 NONE Serial Number : 144102106 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 10 Date Installed : 2011-03-28T14:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : (multiple lines) 4.x Antenna Type : (A20 from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : TROY Tied Marker Usage : FORMER GPS STATION/FOOTPRINT Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : +6.1664 dy (m) : +34.3158 dz (m) : -2.7546 Accuracy (mm) : 2 Survey method : GPS CAMPAIGN Date Measured : 2001-11-26T12:00Z Additional Information : (multiple lines) 5.2 Tied Marker Name : TRY2 Tied Marker Usage : FOOTPRINT Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : +8.3650 dy (m) : -2.4107 dz (m) : -7.2899 Accuracy (mm) : 2 Survey method : GPS CAMPAIGN Date Measured : 2001-11-26T12:00Z Additional Information : (multiple lines) 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2001-11-27/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DDThh:mmZ) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : D3E Electronique Preferred Abbreviation : none Mailing Address : Parc d'activités Savipol - B.P. 55 : 10302 SAINTE-SAVINE CEDEX - FRANCE Primary Contact Contact Name : Bertrand DESPAQUIS Telephone (primary) : (33) 3 25 71 31 54 Telephone (secondary) : none Fax : (33) 3 25 79 95 76 E-mail : gps@d3e.fr Secondary Contact Contact Name : Hervé WYSOCINSKI Telephone (primary) : (33) 3 25 71 31 54 Telephone (secondary) : none Fax : (33) 3 25 79 95 76 E-mail : gps@d3e.fr Additional Information : http://www.d3e.com/d3e.htm 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) : 13. More Information Primary Data Center : RGPCO-SGN Secondary Data Center : RGPCO-SGN URL for More Information : http://rgp.ign.fr Hardcopy on File Site Map : http://rgp.ign.fr Site Diagram : (Y) Horizon Mask : (Y) Monument Description : (Y) Site Pictures : http://rgp.ign.fr Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM55971.00 <-- 0.3396 --> Notches / ----------------------+--------------------- \ + + + \ -------------------------------------------- / \ / \ / \-----+-----/ <-- 0.0000 ARP=BAM | +-+ | Bottom of Pre Amplifier =>|---+====| |====+----|<----------------- -0.0086 (BPA) | | | | Fixed adaptator -------> | | |---------| | |_____|---------| | | | | 10002M010 --->|------------|------|-|-|-|-------|------------| <--- -0.0586 |----------------------------------------------| | | | | | Concrete pillar | | | | | | | BPA: Bottom of Pre Amplifier BCR : Bottom of Choke ring L1 : L1 Phase Center L2 : L2 Phase Center