STJF Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : RGP Team Date Prepared : 2023-12-12 Report Type : NEW If Update : Previous Site Log : Modified/Added Sections : 1. Site Identification of the GNSS Monument Site Name : Saint-Jean-de-Folleville Four Character ID : STJF Monument Inscription : IERS DOMES Number : 18351M001 CDP Number : (A4) Monument Description : Steel mast Height of the Monument : (m) Monument Foundation : top of the steel tower Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 2013-11-25T08:00Z Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Saint-Jean-de-Folleville State or Province : Seine Maritime (76) Country : France Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4151244.402 Y coordinate (m) : 36769.184 Z coordinate (m) : 4825994.614 Latitude (N is +) : +492914.84 Longitude (E is +) : +0003026.92 Elevation (m,ellips.) : 57.81 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GR50 Satellite System : GPS+GLO+GAL Serial Number : 1834341 Firmware Version : 4.31 Elevation Cutoff Setting : 0 Date Installed : 2019-07-20T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+CMP+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAR10 NONE Serial Number : 23179016 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30(m) Date Installed : 2019-07-20T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2023-12-12/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : HAROPA PORT | Rouen Preferred Abbreviation : HAROPA PORT | Rouen Mailing Address : 34, Boulevard de Boisguilbert BP4075 76022 - ROUEN CEDEX 3 Primary Contact Contact Name : Alain HAMEL Telephone (primary) : 06 84 81 88 56 Telephone (secondary) : 02 35 52 54 36 Fax : E-mail : alain.hamel@haropaport.com Secondary Contact Contact Name : Quentin GOMEZ Telephone (primary) : 06 62 54 62 49 Telephone (secondary) : 02 35 52 54 54 Fax : E-mail : quentin.gomez@haropaport.com Additional Information : 12. Responsible Agency (if different from 11.) Agency : Institut National de l'Information Géographique et Forestière Preferred Abbreviation : IGN_RGP Mailing Address : avenue de Paris 73 : 94165 Saint-Mandé Cedex : France Primary Contact Contact Name : RGP Team Telephone (primary) : +33 1 43 98 83 39 Telephone (secondary) : Fax : +33 1 43 98 84 50 E-mail : rgpadmin@ign.fr Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : IGN / Saint-Mande Secondary Data Center : IGN / Marne la Vallee URL for More Information : http://rgp.ign.fr/ Hardcopy on File Site Map : http://rgp.ign.fr Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions LEIAR10 . ^ . <-- 0.1362 . . . . . . . . / \ | | | | <-- 0.0362 Notch +-----____ ____-----+ -----____ ____-\ \- +--x--+ \_\ <-- 0.0000 BAM=ARP <-- 0.2400 -->