PVEC Site Information Form (site log) National Geodetic Survey See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : David A. Cisneros R. Date Prepared : 2016-05-10 Report Type : UPDATE If Update Previous Site Log : pvec_20160229.log Modified/Added Sections : 3.1, 4.1 1. Site Identification of the GNSS Monument Site Name : Portoviejo Four Character ID : PVEC Monument Inscription : IERS DOMES Number : 42008M002 CDP Number : (A4) Monument Description : Concrete pillar built at top of four floor building with force centering device on top. The station is installed in GADM PORTOVIEJO building, Portoviejo city, Manabi Province. Height of the Monument : 2.00 m. Monument Foundation : concrete roof Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 2016-02-26 Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : REGME (Red GNSS de Monitoreo Continuo del Ecuador) The station is installed in GADM PORTOVIEJO building, Portoviejo city, Manabi province. 2. Site Location Information City or Town : Portoviejo State or Province : Manabi Country : Ecuador Tectonic Plate : South American Approximate Position (ITRF) X coordinate (m) : 1042030.87 Y coordinate (m) : -6193799.41 Z coordinate (m) : -1106568.67 Latitude (N is +) : -010328.40 Longitude (E is +) : -0802700.42 Elevation (m,ellips.) : 85.8 Additional Information : Station destroyed by the earthquake Ecuador, April 16, 2016 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO Serial Number : 5045K71488 Firmware Version : 4.81 Elevation Cutoff Setting : 0 Date Installed : 2016-01-26T00:00Z Date Removed : 2016-04-15T23:59Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Station destroyed by the earthquake Ecuador, April 16, 2016 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+CMP+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM59800.00 NONE Serial Number : 5042353996 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2016-01-26T00:00Z Date Removed : 2016-04-15T23:59Z Additional Information : Station destroyed by the earthquake Ecuador, April 16, 2016 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS/GLONASS Status : PERMANENT Effective Dates : 2016-01-26 Notes : Station destroyed by the earthquake Ecuador, April 16, 2016 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Instituto Geografico Militar Preferred Abbreviation : IGM Mailing Address : Seniergues E4-676 y Gral. Telmo Paz y Mino - Quito - Ecuador - Apartado Postal: 17-01-2435 Primary Contact Contact Name : David A. Cisneros R. Telephone (primary) : (593) 2 3975100 Telephone (secondary) : (593) 2 3975101 Fax : (593) 2 3975186 E-mail : david.cisneros@mail.igm.gob.ec Secondary Contact Contact Name : Alberto Chavez Telephone (primary) : (593) 2 3975100 Telephone (secondary) : (593) 2 3975101 Fax : (593) 2 3975186 E-mail : cepge@mail.igm.gob.ec Additional Information : REGME / CEPGE 12. Responsible Agency (if different from 11.) Agency : Instituto Geografico Militar Preferred Abbreviation : IGM Mailing Address : Seniergues E4-676 y Gral. Telmo Paz y Mino - Quito - Ecuador - Apartado Postal: 17-01-2435 Primary Contact Contact Name : David A. Cisneros R. Telephone (primary) : (593) 2 3975100 Telephone (secondary) : (593) 2 3975101 Fax : (593) 2 3975186 E-mail : david.cisneros@mail.igm.gob.ec Secondary Contact Contact Name : Alberto Chavez Telephone (primary) : (593) 2 3975100 Telephone (secondary) : (593) 2 3975101 Fax : (593) 2 3975186 E-mail : alberto.chavez@mail.igm.gob.ec Additional Information : REGME / CEPGE 13. More Information Primary Data Center : IGM (Instituto Geografico Militar) Secondary Data Center : Centro de Procesamiento de Datos GNSS del Ecuador URL for More Information : www.geoportaligm.gob.ec Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : cepge@mail.igm.gob.ec 14. Antenna Graphics with Dimensions TRM59800.00 ------- / \ | | +-----------------+-------------+------------------+ <-- 0.1020 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+--------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.000 BPA=ARP <-- 0.3810 -->