PASA Site Information Form International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Mikelo Elorza Date Prepared : 2014-07-11 Report Type : UPDATE If Update: Previous Site Log : (pas2_20140711.log) Modified/Added Sections : 4.2, 4.3 1. Site Identification of the GNSS Monument Site Name : Pasaia Four Character ID : PAS2 Monument Inscription : IERS DOMES Number : 19351S001 CDP Number : Monument Description : STEEL MAST Height of the Monument : 1.7 m Monument Foundation : MAST SCREW ANCHORED TO BUILDING WALL Foundation Depth : Marker Description : Date Installed : 2007-02-12 Geologic Characteristic : Bedrock Type : LIMESTONE Bedrock Condition : Fracture Spacing : Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : The monument is on the roof of the : AZTI-Tecnalia centre of Pasaia : Antenna is approximately 15m above ground level 2. Site Location Information City or Town : Pasaia State or Province : Gipuzkoa Country : Spain Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4657557.4678 Y coordinate (m) : -202242.7274 Z coordinate (m) : 4338992.6355 Latitude (N is +) : +431918.35 Longitude (E is +) : -0015553.45 Elevation (m,ellips.) : 67.33 Additional Information : Permanent GNSS and Tide Gauge 3. GNSS Receiver Information 3.1 Receiver Type : TPS NET-G3A Satellite System : GPS+GLO Serial Number : KRD0K9AF0U8 Firmware Version : 4.1 May,31,2013 Elevation Cutoff Setting : 0 deg Date Installed : 2014-04-01 Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : NONE Additional Information : Receiver connected to ALDCBS1X2 : amplified signal splitter : The first output of the splitter is connected with : the receiver of station PASA 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAR20 LEIM Serial Number : 16073034 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIM Radome Serial Number : Unknown Antenna Cable Type : Leica+splitter+RG-223 Antenna Cable Length : 30+1 m Date Installed : 2013-12-17 Date Removed : 2014-07-11 Additional Information : SECO Leveling Mount 4.2 Antenna Type : LEIAR20 LEIM Serial Number : 16073034 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIM Radome Serial Number : Unknown Antenna Cable Type : Leica+Splitter+RG-223 Antenna Cable Length : 30 m Date Installed : 2014-07-11 Date Removed : 2014-10-20 Additional Information : SECO Leveling Mount : A 0.6x0.6 m^2 metal shield was : installed with Eccosorb ANW-77 on top. The : spacing between the BPA and the top of the : Eccosorb is 8.6 cm 4.3 Antenna Type : LEIAT504GG LEIS Serial Number : 102842 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIS Radome Serial Number : Unknown Antenna Cable Type : Leica+Splitter+RG-223 Antenna Cable Length : 30 m Date Installed : 2014-10-20 Date Removed : CCYY-MM-DDThh:mmZ Additional Information : SECO Leveling Mount : A 0.6x0.6 m^2 metal shield was : installed with Eccosorb ANW-77 on top. The : spacing between the BPA and the top of the : Eccosorb is 8.6 cm 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2014-04-01/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : Tide Gauge Status : PERMANENT Effective Dates : 2007-02-19/CCYY-MM-DD Notes : Paroscientific Series 8000 Gauge 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC Serial Number : DQ107250 Data Sampling Interval : 600 sec Accuracy (% rel h) : 2 % rel h Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2009-03-04/2011-04-08 Notes : (multiple lines) 8.1.2 Humidity Sensor Model : MET3 Manufacturer : PAROSCIENTIFIC Serial Number : DQ 96233 Data Sampling Interval : 600 sec Accuracy (% rel h) : 2 % rel h Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2011-06-06/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC Serial Number : DQ107250 Data Sampling Interval : 600 sec Accuracy : 0.08 hPa Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2009-03-04/2011-04-08 Notes : (multiple lines) 8.2.2 Pressure Sensor Model : MET3 Manufacturer : PAROSCIENTIFIC Serial Number : DQ 96233 Data Sampling Interval : 600 sec Accuracy : 0.08 hPa Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2011-06-06/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC Serial Number : DQ107250 Data Sampling Interval : 600 sec Accuracy : 0.5 deg C Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2009-03-04/2011-04-08 Notes : (multiple lines) 8.3.2 Temp. Sensor Model : MET3 Manufacturer : PAROSCIENTIFIC Serial Number : DQ 96233 Data Sampling Interval : 600 sec Accuracy : 0.5 deg C Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -1.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2011-06-06/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Department of Applied Geodesy : Aranzadi Society of Sciences Preferred Abbreviation : ADAG Mailing Address : Aranzadi Zientzi Elkartea : Department of Applied Geodesy : Zorroagagaina, 11 : Donostia - San Sebastian : E-20014 Spain Primary Contact Contact Name : Dr. Jokin Zurutuza (ADAG) Telephone (primary) : +34-943466124 Telephone (secondary) : Fax : E-mail : geodesia@aranzadi-zientziak.org Secondary Contact Contact Name : Andoitz Antzizar (ADAG) Telephone (primary) : +34-943466124 Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Gipuzkoako Foru Aldundia : Diputacion Foral de Gipuzkoa Preferred Abbreviation : GFA-DFG Mailing Address : Lurralde Plangintza : Planificación Territorial : Julio Caro Baroja 2 : Donostia - San Sebastian : E-20018 Spain Primary Contact Contact Name : Mikelo Elorza Telephone (primary) : +34-943112806 Telephone (secondary) : Fax : E-mail : melorza@gipuzkoa.net Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : GFA-DFG Secondary Data Center : URL for More Information : b5m.gipuzkoa.net/web5000/en/geodesy/ : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : Additional Information : (multiple lines) Antenna Graphics with Dimensions LEIAR20 +-----+ <-- 0.1613 / \ | | +----------------+-----------+----------------+ <-- 0.1113 TCR | | | | | | | | +-+---------------------------------------------+-+ +------------------+-----------+------------------+ <-- 0.0323 BCR | | | | +-----x-----+ <-- 0.0013 BPA +-+ <-- 0.0000 BAM=ARP <-- 0.3200 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering BPA: Bottom of Preamplifier