NJGT Site Information Form SMRTNT Continuously Operating Reference Station See Instructions at: ftp://www.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Francine Coloma Date Prepared : 2017-08-03 Report Type : UPDATE If Update: Previous Site Log : njgt_20160128.log Modified/Added Sections : 1, 3.5, 4.2 1. Site Identification of the GNSS Monument Site Name : R Stockton Coll Four Character ID : NJGT Monument Inscription : IERS DOMES Number : (A9) CDP Number : (A4) Monument Description : Stainless Steel Mast Height of the Monument : 5.03 m Monument Foundation : Masonry Building Wall Foundation Depth : 1 m Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 2007-09-25T00:00Z Geologic Characteristic : SAND Bedrock Type : SEDIMENTARY Bedrock Condition : UNCONSOLIDATED Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : 03-AUG-2017 site DECOMMISSIONED 2. Site Location Information City or Town : Galloway Township State or Province : New Jersey Country : United States Tectonic Plate : North American Approximate Position (ITRF) X coordinate (m) : 1314928.268 Y coordinate (m) : -4751401.307 Z coordinate (m) : 4033112.698 Latitude (N is +) : +392828.28 Longitude (E is +) : -0743150.95 Elevation (m,ellips.) : -12.4 Additional Information : ARP IGS08 POSITION (EPOCH 2005.00) : Computed in Aug 2011 using data through gpswk : 1631. 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355151 Firmware Version : 5.60/3.014 Elevation Cutoff Setting : 5 deg Date Installed : 2007-09-25 Date Removed : 2009-08-21 Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Elevation changed. 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355151 Firmware Version : 5.60/3.014 Elevation Cutoff Setting : 0 deg Date Installed : 2009-08-21 Date Removed : 2012-10-09 Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Firmware upgrade 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355151 Firmware Version : 8.51/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2012-10-09 Date Removed : 2014-03-05T01:20Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Firmware updated 3.4 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355151 Firmware Version : 8.71/3.822 Elevation Cutoff Setting : 0 deg Date Installed : 2014-03-05T01:20Z Date Removed : 2016-01-19T15:00Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Receiver change 3.5 Receiver Type : LEICA GR10 Satellite System : GPS+GLO Serial Number : 1703970 Firmware Version : 3.22/6.521 Elevation Cutoff Setting : 0 deg Date Installed : 2016-01-19T16:56Z Date Removed : 2017-08-03T15:00Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : 03-AUG-2017 site DECOMMISSIONED 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAT504GG LEIS Serial Number : 200277 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIS Radome Serial Number : Antenna Cable Type : LMR 400 Antenna Cable Length : 27.7 m Date Installed : 2007-09-25 Date Removed : 2016-01-19T15:00Z Additional Information : Antenna change 4.2 Antenna Type : LEIAR10 NONE Serial Number : 18283010 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : LMR 400 Antenna Cable Length : 27.7 m Date Installed : 2016-01-19T16:56Z Date Removed : 2017-08-03T15:00Z Additional Information : 03-AUG-2017 site DECOMMISSIONED 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2007-09-25/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interference : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interference : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Richard Stockton College of New Jersey Preferred Abbreviation : STOCOL Mailing Address : Wilson Avenue Port Republic, NJ 08241 Primary Contact Contact Name : Dr. Stewart Farrell Telephone (primary) : (609) 652-4245 Telephone (secondary) : Fax : (609) 748-0656 E-mail : Stewart.Farrell@stockton.edu Secondary Contact Contact Name : Frank Lenik, PLS Telephone (primary) : (856) 769-9218 Telephone (secondary) : (856) 275-3210 Fax : (856) 769-0246 E-mail : frank.lenik@leicaus.com Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : New Jersey Institute of Technology Preferred Abbreviation : NJIT Mailing Address : 323 Martin Luther King Boulevard : Newark, NJ 07102 Primary Contact Contact Name : Joshua S. Greenfeld, Ph.D. Telephone (primary) : (973) 596-5808 Telephone (secondary) : (973) 596-8497 Fax : (973) 242-1823 E-mail : greenfeld@adm.njit.edu Secondary Contact Contact Name : Frank Lenik, PLS Telephone (primary) : (856) 769-9218 Telephone (secondary) : (856) 275-3210 Fax : (856) 769-0246 E-mail : frank.lenik@leicaus.com Additional Information : (multiple lines) 13. More Information Primary Data Center : ftp://geodesy.noaa.gov/cors Secondary Data Center : ftp://alt.ngs.noaa.gov/cors URL for More Information : http://geodesy.noaa.gov/CORS Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions ftp://www.igs.org/pub/station/general/antenna.gra