IDBY00USA Site Information Form SmartNet North America See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Don Haw as per Ian Drake Date Prepared : 2023-05-02 Report Type : UPDATE If Update: Previous Site Log : idby_20200408.log Modified/Added Sections : 3.4 1. Site Identification of the GNSS Monument Site Name : Rexburg Four Character ID : IDBY Monument Inscription : IERS DOMES Number : (A9) CDP Number : (A4) Monument Description : ALUMINUM PIPE MAST Height of the Monument : 2 m Monument Foundation : ROOF Foundation Depth : (m) Marker Description : Date Installed : 2005-09-01T00:00Z Geologic Characteristic : Bedrock Type : IGNEOUS Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : The mast is a heavy gauge aluminum pipe 3" : diameter (7.6cm) with a square 10" plate : ~25cm)welded to the bottom of the pipe which : is attached to the wall of the building by : bolts that extend through the wall with : fasteners on the inside. Approximately 28 : inches above the plate, a 3" strap, also : welded to the pipe, is bolted to the wall : to provide additional support. The mast : extends about 2 meters above the roof top. : The building is approximately ~14.3 m. Bldg : foundation is a concrete slab poured over : basalt 2. Site Location Information City or Town : Rexburg State or Province : Idaho Country : United States Tectonic Plate : North American Approximate Position (ITRF) X coordinate (m) : -1710923.768 Y coordinate (m) : -4281179.100 Z coordinate (m) : 4394745.901 Latitude (N is +) : +434913.30 Longitude (E is +) : -1114700.78 Elevation (m,ellips.) : 1493.1 Additional Information : ARP IGS08 POSITION (EPOCH 2005.00) : Computed in Aug 2011 using data through gpswk : 1631. 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GRX1200PRO Satellite System : GPS Serial Number : 456883 Firmware Version : 2.10 Elevation Cutoff Setting : (deg) Date Installed : 2005-09-01 Date Removed : 2012-11-09 Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : Receiver internal electronics updated by Leica : to receive GLONASS signal. Same external box, : so serial number did not change. 3.2 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 456883 Firmware Version : 8.51/6.111 Elevation Cutoff Setting : 10 deg Date Installed : 2012-11-09 Date Removed : 2019-02-06T19:43Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 3.3 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 456883 Firmware Version : 9.20/6.405 Elevation Cutoff Setting : 0 deg Date Installed : 2019-02-06T19:43Z Date Removed : 2023-04-27T14:00Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : firmware upgrade 3.4 Receiver Type : LEICA GR50 Satellite System : GPS+GLO Serial Number : 2091029 Firmware Version : 4.61/7.811 Elevation Cutoff Setting : 0 deg Date Installed : 2023-04-27T14:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : new receiver 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAX1202 NONE Serial Number : 05110096 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2005-09-01 Date Removed : 2006-02-20 Additional Information : Antenna mast removed to attach levelling : and orienting device. 4.2 Antenna Type : LEIAX1202 NONE Serial Number : 05110096 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : -90 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2006-03-17 Date Removed : 2012-11-07 Additional Information : During removal of old antenna, Mark Lovell the : Data Provider discovered antenna was oriented : due west, instead of north. Edited 4.2 value : on 15-NOV-2012 to "-90 deg" 4.3 Antenna Type : LEIAS10 NONE Serial Number : 12091060 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2012-11-09 Date Removed : 2016-06-22T14:30Z Additional Information : Antenna change 4.4 Antenna Type : LEIAR10 NONE Serial Number : 18344008 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2016-06-22T14:50Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2005-09-01/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interference : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interference : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Brigham Young University-Idaho Preferred Abbreviation : BYUI Mailing Address : 524 South Center Street, : Rexburg, ID 83460-0510 Primary Contact Contact Name : Mark Lovell Telephone (primary) : 208-496-1903 Telephone (secondary) : Fax : E-mail : lovellm@byui.edu Secondary Contact Contact Name : Jeannine Nielson Telephone (primary) : 208-496-1905 Telephone (secondary) : Fax : E-mail : nielsonjj@byui.edu Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : SmartNet North America Preferred Abbreviation : SMRTNT Mailing Address : 5051 Peachtree Corners Circle : Suite 250 : Norcross, Georgia 30092 Primary Contact Contact Name : SmartNet NA Telephone (primary) : 770-326-9500 x 1430 Telephone (secondary) : Fax : E-mail : support@smartnetna.com Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : ftp://rinex.smartnetna.com Secondary Data Center : https://geodesy.noaa.gov/corsdata// URL for More Information : http://www.smartnetna.com Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : https://geodesy.noaa.gov/CORS/ Additional Information : (multiple lines) Antenna Graphics with Dimensions https://files.igs.org/pub/station/general/antenna.gra