CEEC00ECU Site Information Form (site log) International GNSS Service See Instructions at: https://ftp.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : William Alejandro Martínez Garrido Date Prepared : 2021-04-29 Report Type : UPDATE If Update Previous Site Log : ceec00ecu_20200113.log Modified/Added Sections : 3.2 1. Site Identification of the GNSS Monument Site Name : Celica Four Character ID : CEEC Monument Inscription : IERS DOMES Number : 42031M002 CDP Number : Monument Description : Stainless steel pyramidal structure with force centering device on top. The station is installed in the Batallón de Infantería Motorizado No. 19 "Carchi", in Celica city, Loja province. Height of the Monument : 2.19 m Monument Foundation : concrete floor Foundation Depth : 0.50 m Marker Description : Date Installed : 2019-11-30T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : REGME (Red GNSS de Monitoreo Continuo del Ecuador-Instituto Geografico Militar-IGM Quito) 2. Site Location Information City or Town : Celica State or Province : Loja Country : Ecuador Tectonic Plate : South American Approximate Position (ITRF) X coordinate (m) : 1109961.79 Y coordinate (m) : -6266411.53 Z coordinate (m) : -453223.36 Latitude (N is +) : -040603.31 Longitude (E is +) : -0795719.62 Elevation (m,ellips.) : 2045.1 Additional Information : REGME Network 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO Serial Number : 5826R40021 Firmware Version : 5.37 Elevation Cutoff Setting : 0 Date Installed : 2019-11-30T00:00Z Date Removed : 2021-03-02T12:00Z Temperature Stabiliz. : NONE Additional Information : REGME Network 3.2 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO Serial Number : 5826R40021 Firmware Version : 5.45 Elevation Cutoff Setting : 0 Date Installed : 2021-03-02T13:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : NONE Additional Information : REGME Network 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is use Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM159900.00 SCIS Serial Number : 5842338426 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.000 Marker->ARP North Ecc(m) : 0.000 Marker->ARP East Ecc(m) : 0.000 Alignment from True N : 0 Antenna Radome Type : SCIS Radome Serial Number : 2382 Antenna Cable Type : LMR400 Antenna Cable Length : 30 Date Installed : 2019-11-30T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS/GLONASS Status : PERMANENT Effective Dates : 2019-11-30 Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : MET4A Manufacturer : Paroscientific,Inc. Serial Number : 128686 Data Sampling Interval : 350 sec Accuracy (% rel h) : % Aspiration : FAN Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : 2019-11-30/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : MET4A Manufacturer : Paroscientific,Inc. Serial Number : 128686 Data Sampling Interval : 350 sec Accuracy : hPa Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : 2019-11-30/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : MET4A Manufacturer : Paroscientific,Inc. Serial Number : 128686 Data Sampling Interval : 350 sec Accuracy : deg C Aspiration : FAN Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : 2019-11-30/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Batallón de Infantería Motorizado No. 19 "CARCHI" Preferred Abbreviation : BS 19. "CARCHI" Mailing Address : Primary Contact : Instituto Geografico Militar Contact Name : Proceso de Geodesia Telephone (primary) : +593 23 975 100 Ext 2013 Telephone (secondary) : Fax : E-mail : procesogeodesia.igm@geograficomilitar.gob.ec Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Instituto Geografico Militar Preferred Abbreviation : IGM Mailing Address : Av. Seniergues E4-676 y Gral. Telmo Paz y Miño Quito - Ecuador Apartado: 17-01-2435 Primary Contact Contact Name : William Alejandro Martinez Telephone (primary) : +593 23 975 100 Ext 2013 Telephone (secondary) : +593 98 462 0114 Fax : E-mail : alejandro.martinez@geograficomilitar.gob.ec Secondary Contact Contact Name : Marco Vinicio Amores Telephone (primary) : +593 23 975 100 Ext 2013 Telephone (secondary) : +593 98 453 2635 Fax : E-mail : marco.amores@geograficomilitar.gob.ec Additional Information : Centro de Procesamiento de Datos GNSS del Ecuador - IGM (Quito-Ecuador) 13. More Information Primary Data Center : IGM (Instituto Geografico Militar) Secondary Data Center : CEPGE (Quito, Ecuador) URL for More Information : http://www.geoportaligm.gob.ec/portal /index.php/datos-geodesicos/ Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : 14. Antenna Graphics with Dimensions TRM159800.00 TRM159900.00 TRM29659.00 TRM59800.00 TRM59800.00C TRM59800.80 TRM59900.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 -->