CALL00PER Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : HERBERT ARENZ Date Prepared : 2018-03-23 Report Type : UPDATE If Update: Previous Site Log : call_20150205.log Modified/Added Sections : 3.4, 4.1 1. Site Identification of the GNSS Monument Site Name : EL CALLAO Four Character ID : CALL Monument Inscription : IERS DOMES Number : 42205M001 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : 1.475 Monument Foundation : ROOF Foundation Depth : (m) Marker Description : The reference point is a brass plate on top of the pillar. Date Installed : 2009-07-01 Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : Concrete pillar of 1.475m height anchored on the roof of the building 'convention center' in the Fort Castillo del Real Felipe in the city Callao. The reference point is a brass plate on top of the pillar, the antenna being fixed by a 110mm high base above the plate. 2. Site Location Information City or Town : EL CALLAO State or Province : LIMA Country : PERU Tectonic Plate : SOAM Approximate Position (ITRF) X coordinate (m) : 1387454.1 Y coordinate (m) : -6081996.2 Z coordinate (m) : -1324212.2 Latitude (N is +) : -120346.3 Longitude (E is +) : -0770857.5 Elevation (m,ellips.) : 33.8 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355517 Firmware Version : 7.02/3.016 Elevation Cutoff Setting : 0.0 Date Installed : 2009-07-03T12:00Z Date Removed : 2009-09-17T08:44Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355517 Firmware Version : 7.53/3.017 Elevation Cutoff Setting : 0.0 Date Installed : 2009-09-17T09:14Z Date Removed : 2010-06-29T11:32Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355517 Firmware Version : 7.80/3.019 Elevation Cutoff Setting : 0.0 Date Installed : 2010-06-29T12:35Z Date Removed : 2014-07-22T07:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.4 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355517 Firmware Version : 8.71/3.822 Elevation Cutoff Setting : 0.0 Date Installed : 2014-07-22T07:49Z Date Removed : 2018-04-26T23:59Z Temperature Stabiliz. : none Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAT504GG LEIS Serial Number : 200592 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1100 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 121 deg Antenna Radome Type : LEIS Radome Serial Number : Antenna Cable Type : H.u.S. SUCOFEED 3/8_HF_FR Antenna Cable Length : 30 m Date Installed : 2009-07-03T12:00Z Date Removed : 2018-04-26T23:59Z Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : INSTITUTO GEOGRAFICO NACIONAL PERU Preferred Abbreviation : IGN PERU Mailing Address : AV. ARAMBURU 1190-1198 LIMA, PERU Primary Contact Contact Name : EDGAR HUARAJO CASAVERDE Telephone (primary) : 51-1-475-3030 Ext. 120 Telephone (secondary) : 51-1-475-3030 Ext. 220 Fax : 51-1-475-3075 E-mail : edgar_hc2002@hotmail.com Secondary Contact Contact Name : JULIO SAENZ Telephone (primary) : Telephone (secondary) : Fax : E-mail : juliosaenz_27@hotmail.com Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : DEUTSCHES GEODAETISCHES FORSCHUNSINSTITUT DER TECHNISCHEN UNIVERSITAET MUENCHEN Preferred Abbreviation : DGFI-TUM Mailing Address : ALFONS-GOPPEL-STR. 11 D-80539 MUNICH, GERMANY Primary Contact Contact Name : HERBERT ARENZ Telephone (primary) : (49) 89 23031 1105 Telephone (secondary) : (49) 89 23031 1110 Fax : (49) 89 23031 1240 E-mail : herbert.arenz@tum.de Secondary Contact Contact Name : LAURA SANCHEZ Telephone (primary) : (49) 89 23031 1295 Telephone (secondary) : Fax : E-mail : lm.sanchez@tum.de Additional Information : (multiple lines) 13. More Information Primary Data Center : DGFI-TUM Secondary Data Center : URL for More Information : www.sirgas.org Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions (insert text graphic from file antenna.gra) LEIAT504GG +-------+ <-- 0.1393 / \ | | +-----------------+-------------+-----------------+ <-- 0.1012 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0378 +-------------------+-------------+-------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3794 -->