BFO1 Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : TEAM SAPOS Date Prepared : 2017-07-31 Report Type : UPDATE If Update: Previous Site Log : Modified/Added Sections : 2,3.1,4.1,12,5.1,3.2,4.2 1. Site Identification of the GNSS Monument Site Name : Black Forest Observatory Four Character ID : BFO1 Monument Inscription : BFO1 IERS DOMES Number : 10907M001 CDP Number : (A4) Monument Description : ALUMINUM TRIPOD Height of the Monument : 3.60 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 0.5 - 1 m Marker Description : BRASS NAIL Date Installed : 2006-11-14T14:00Z Geologic Characteristic : BEDROCK Bedrock Type : IGNEOUS Bedrock Condition : WEATHERED Fracture Spacing : 11-50 cm Fault zones nearby : YES, Rhine graben Distance/activity : 35 km to the main fault running N-S along the east side of the graben. Additional Information : http://www.bfo.geophys.uni-stuttgart.de/GPS/GPS.html 2. Site Location Information City or Town : SCHILTACH State or Province : BADEN-WUERTTEMBERG Country : GERMANY Tectonic Plate : EURASIAN PLATE Approximate Position (ITRF) X coordinate (m) : 4204025.943 Y coordinate (m) : 615170.248 Z coordinate (m) : 4741902.986 Latitude (N is +) : +481949.79 Longitude (E is +) : +0081929.79 Elevation (m,ellips.) : 690.3 Additional Information : ETRS89/DREF91(R2016) 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4700 Satellite System : GPS Serial Number : 0220222630 Firmware Version : 1.3 Elevation Cutoff Setting : 0 DEG Date Installed : 2006-11-14T12:00Z Date Removed : 2017-03-08T10:00Z Temperature Stabiliz. : none Additional Information : The receiver is housed inside the magnetics : hut. Uninteruptable 220V power is supplied from the : observatory via a burried 200m long cable. Serial : data communication (RS-232) is realized via a fiber : optic link to the laboratory building and from there on via : DSL to the internet. 3.2 Receiver Type : SEPT POLARX5 Satellite System : GPS+GLO+GAL Serial Number : 3014122 Firmware Version : 5.1.0 Elevation Cutoff Setting : 0 DEG Date Installed : 2017-03-08T10:00Z Date Removed : Temperature Stabiliz. : NONE Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM29659.00 Serial Number : 0220227657 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 3.603 Marker->ARP North Ecc(m) : 0.000 Marker->ARP East Ecc(m) : 0.000 Alignment from True N : 0 Antenna Radome Type : TCWD Radome Serial Number : Antenna Cable Type : NONE Antenna Cable Length : 30m Date Installed : 2006-11-14T00:00Z Date Removed : 2017-03-08T10:00Z Additional Information : Antenna including the Radome were phase : calibrated in spring of 2008 by Geo++ : in Hannover (Germany). The results of the : calibration can be downloaded from : www.geophys.uni-stuttgart.de/~widmer/GPS/ 4.2 Antenna Type : SEPCHOKE_B3E6 SPKE Serial Number : 5089 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 3.603 Marker->ARP North Ecc(m) : 0.000 Marker->ARP East Ecc(m) : 0.000 Alignment from True N : 0 Antenna Radome Type : SPKE Radome Serial Number : Antenna Cable Type : NONE Antenna Cable Length : 30 Date Installed : 2017-03-08T10:00Z Date Removed : Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : 0428 Tied Marker Usage : Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 0.000 dy (m) : 0.000 dz (m) : 0.000 Accuracy (mm) : Survey method : Date Measured : Additional Information : STATION USED FOR RTK-MONITORING BY LGL 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2006-11-14 Notes : NONE 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMT330 Manufacturer : Vaisala Oyj Serial Number : RC2850076 Data Sampling Interval : 15s Accuracy (% rel h) : 1% Aspiration : UNASPIRATED Height Diff to Ant : -0.5m Calibration date : 2006-09-29T00:00Z Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Parosci 6000-16B Manufacturer : Paroscientific Serial Number : 90720 Data Sampling Interval : 1 sec Accuracy : 0.001 hPa Height Diff to Ant : -1.5 m Calibration date : 2003-10-22T00:00Z Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : Microbarometer data is shipped to the : IRIS/DMC (www.iris.edu) and : published under : network code: II : station code: BFO : channel code: LDO : location code 10 : A copy of this data with lower : resolution and lower sample rate : is published in the RINEX.met files. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMT330 Manufacturer : Vaisala Oyj Serial Number : RC2850076 Data Sampling Interval : 15s Accuracy : 0.1 deg C Aspiration : UNASPIRATED Height Diff to Ant : -0.5m Calibration date : 2006-09-29T00:00Z Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Black Forest Observatory : Karlsruhe Institute of Technology (KIT) and Stuttgart University Preferred Abbreviation : BFO Mailing Address : Black Forest Observatory : Heubach 206 : D-77709 Wolfach : Germany Primary Contact Contact Name : Rudolf Widmer-Schnidrig Telephone (primary) : +49 7836 2151 Telephone (secondary) : +49 711 685 87400 Fax : +49 7836 955240 E-mail : widmer@geophys.uni-stuttgart.de Secondary Contact Contact Name : Michael Mayer Telephone (primary) : +0049 721 608 42724 Telephone (secondary) : Fax : +0049 721 608 46808 E-mail : michael.mayer@kit.edu Additional Information : 12. Responsible Agency (if different from 11.) Agency : LGL BADEN-WUERTTEMBERG Preferred Abbreviation : LGL Mailing Address : KRIEGSSTRASSE 103 : 76135 KARLSRUHE Primary Contact Contact Name : DENIS KLEINECKE Telephone (primary) : 0049-721-95980-494 Telephone (secondary) : Fax : 0049-721-9598092-494 E-mail : DENIS.KLEINECKE@LGL.BWL.DE Secondary Contact Contact Name : TEAM SAPOS Telephone (primary) : 0049-170-8572321 Telephone (secondary) : Fax : E-mail : SAPOS@LGL.BWL.DE Additional Information : 13. More Information Primary Data Center : LGL BW Secondary Data Center : URL for More Information : HTTP://WWW.LGL-BW.DE Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : Y Additional Information : Antenna Graphics with Dimensions SEPCHOKE_B3E6 --------------- <-- 0.1550 / \ | | +-----------------------------------------------------+ <-- 0.1080 TCR | | | | | | | | +-----------------+-----------------+-----------------+ <-- 0.0480 BCR | | | | | | +--------x--------+ <-- 0.0000 BAM=ARP NOM=NRP <-- 0.1210 --> <-- 0.3630 -->